A laser for research laboratories has a different centre of gravity from workshop work. Repeatability, beam quality and documented safety controls matter more than raw output, and the institution’s own laser safety rules always sit on top of anything a supplier tells you.

Laser beam aligned across an optical bench in a darkened laboratory with beam blocks in place
Laboratory laser work: a controlled beam path, a beam stop at the end of it, and wavelength-matched eyewear for everyone in the room.

Bench work versus instrument integration

Two routes cover most laboratory requirements. The first is a handheld Class 4 unit used on a fixed mount for alignment, sample illumination or demonstration, with the beam contained by a beam stop and the operators in wavelength-matched eyewear. The second is a fixed laser module or head integrated into an instrument, where the module is enclosed and interlocked and the beam path never leaves the housing.

Both routes need the same three numbers documented before purchase: optical output at the aperture, wavelength and its tolerance, and beam divergence or spot size. Everything we publish on a product page is written so it can be pasted straight into a risk assessment or a purchase justification.

Selecting power and wavelength

ConsiderationWhat to checkWhy it matters in a lab
Optical outputRated output in watts or milliwatts at the aperture, with the manufacturer’s toleranceDetermines the hazard class, the nominal hazard distance and the optical density requirement
Wavelength450 nm blue diode for portable bench work; 1080 nm fibre for the mains-powered machinesEyewear, detector response and sample absorption are all wavelength-specific
Beam qualityDivergence, focus type and whether the lens is adjustableDecides whether the spot is tight enough for the experiment and how it behaves over distance
StabilityDuty cycle and cooling methodA thermally drifting source invalidates long-duration measurements
MountingTripod thread, rail or bracket compatibilityAlignment stability, and whether the beam path can be fixed and interlocked

The controls a laboratory is expected to apply

  1. A laser safety officer or responsible person signs off the setup and the class of every source in the room.
  2. Containment first. Enclosures and beam blocks so the beam terminates, with the beam path kept below eye level and away from walkways.
  3. Wavelength-matched eyewear for everyone in the room, not only the operator. Blue 450 nm work needs OD5+ for the mid and professional handheld units; 1080 nm fibre work needs OD6+ rated at that wavelength.
  4. Warning signage and interlocks on the room or the enclosure, with access restricted to trained people.
  5. Alignment done at minimum power, and never with the eye on the beam axis.
  6. Documented standard: most laboratories work to ANSI Z136.1 in the United States or IEC 60825-1 elsewhere, plus local occupational health rules. Your institution’s own procedure takes precedence.

Read the full laser safety and responsible use guide for the handling, storage and transport rules that apply to every product we sell, and the laser classes guide for how classes are defined.

Mains-powered fibre machines in a laboratory or facility

The 750 W – 2 000 W machines in our range are 1080 nm Class 4 fibre systems on 220–240 V AC with water cooling. They are fixed installations: they need a dedicated supply, a chiller with airflow, a controlled area with restricted access, and eye protection rated OD6+ at 1064 nm for anyone inside that area. These units fall outside Canada’s prohibition on handheld Class 3B and Class 4 lasers because they require a mains connection to operate, but laser products imported into Canada still have to meet the Radiation Emitting Devices Act requirements, and buyers elsewhere must confirm their own import eligibility. Ask us before ordering one for an institutional site and we will go through the requirements with you.

Purchase orders, documentation and eligibility

We supply businesses, research groups, colleges and museums, and we can invoice an organisation directly. To set that up, send the organisation name, the billing and delivery details, the quantity and the destination country through contact, and see wholesale, trade and education for how those orders work. Two limits apply to every order, institutional or not: we sell to adults aged 18 and over only, and we do not deliver to destinations that prohibit the import of the device.

What we can and cannot document: we provide the published specification, the manufacturer’s stated ratings and the manufacturer’s warranty terms for every unit. We do not issue calibration certificates or independent test reports, and we will not claim a certification the manufacturer has not provided. If your risk assessment needs more, tell us what the requirement is before you order.

Browse the range Request a written specification